This is a static copy of data that is exported from IATE on an occasional basis. It should not be assumed that information provided about an entry here will always correspond to the current version of the entry in IATE. That current version can be checked by clicking on the link on the upper right hand side of each entry. More information »

6 results

  1. ENERGY|electrical and nuclear industries|electrical industry · PRODUCTION, TECHNOLOGY AND RESEARCH|technology and technical regulations|technical regulations
    díscor éilimh ísealvoltais mar fhreagairt ar an éileamh Reference Faomhadh an téarma seo mar chuid de Thionscadal Lex
    ga
    demand side response low voltage demand disconnection | DSR LVDD
    en
    Definition "demand within a demand facility [ IATE:3552552 ] or closed distribution network [ IATE:3552910 ] that can be disconnected in case of low voltage" Reference "European Network of Transmission System Operators for Electricity (ENTSO-E), Glossary > demand side response low voltage demand disconnection, https://emr.entsoe.eu/glossary/bin/view/CustomizationsCode/Term?termID=c3b583f6-a230-49a5-95aa-865ea0cb2546&cid=930 [23.11.2015]"
  2. ENERGY|energy policy · ENERGY|electrical and nuclear industries|electrical industry · PRODUCTION, TECHNOLOGY AND RESEARCH|technology and technical regulations|technical regulations
    díscor éilimh i gcás ísealvoltais Reference Faomhadh an téarma seo mar chuid de Thionscadal Lex
    ga
    Lasttrennung bei Unterspannung
    de
    Definition Trennung einer Last vom Netz aufgrund einer Unterspannung mit dem Ziel, die Spannung wieder auf eine tragfähige Höhe und innerhalb akzeptabler Grenzen zu bringen Reference COM-Internes Dokument ENER-2015-80065: Verordnung der Kommission zur Festlegung eines Netzkodex für den Abnehmeranschluss
    low voltage demand disconnection | LVDD
    en
    Definition "restoration action where demand [ IATE:1691306 ] is disconnected during a low voltage event in order to recover voltage to a sustainable level within acceptable limits" Reference "European Network of Transmission System Operators for Electricity (ENTSO-E), Glossary > low voltage demand disconnection, https://emr.entsoe.eu/glossary/bin/view/CustomizationsCode/Term?termID=ba4b7399-7b1c-4966-9892-d1452f71b313&cid=1633 [24.11.2015]"
  3. EUROPEAN UNION|European Union law|EU act|directive (EU) · TRADE · ENERGY
    Treoir 2014/35/AE maidir le comhchuibhiú dhlíthe na mBallstát a bhaineann le trealamh leictreach a chur ar fáil ar an margadh, ar trealamh é a dheartar lena úsáid laistigh de theorainneacha áirithe voltais Reference "Rialachán (AE) 2016/426 maidir le fearais a dhónn breoslaí gásacha"
    ga
    Treoir 2014/35/AE maidir le comhfhogasú dhlíthe na mBallstát a bhaineann le trealamh leictreach a chur ar fáil ar an margadh, ar trealamh é a dheartar lena úsáid laistigh de theorainneacha áirithe voltais Reference "Rialachán (AE) 2019/1020 maidir le faireachas margaidh ar tháirgí agus comhlíonadh táirgí"
    ga
    Low Voltage Directive | Directive 2014/35/EU of the European Parliament and of the Council of 26 February 2014 on the harmonisation of the laws of the Member States relating to the making available on the market of electrical equipment designed for use within certain voltage limits (recast)
    en
    Comment "The first Low Voltage Directive (73/23/EEC) was adopted in 1973. It was later amended and then codified and replaced by a second Low Voltage Directive (2006/95/EC) which in turn was repealed and replaced by the current Low Voltage Directive 2014/53/EU."
    directive basse tension | Directive 2014/35/UE du Parlement européen et du Conseil du 26 février 2014 relative à l’harmonisation des législations des États membres concernant la mise à disposition sur le marché du matériel électrique destiné à être employé dans certaines limites de tension (refonte)
    fr
    Definition directive en application depuis 2016, qui garantit que le matériel électrique employé dans certaines limites de tension offre un niveau élevé de protection aux citoyens européens et bénéficie pleinement des avantages du marché unique Reference "Communication de la Commission au Parlement européen, au Conseil, au Comité économique et social européen et au Comité des régions Programme de travail de la Commission pour 2020 Une Union plus ambitieuse"
  4. ENERGY · INDUSTRY|electronics and electrical engineering
    soláthar cumhachta seachtrach ísealvoltais Reference Téarmeolaithe COM-GA
    ga
    SCS ísealvoltais Reference Téarmeolaithe COM-GA
    ga
    low voltage external power supply | low-voltage EPS
    en
    Definition "external power supply with a nameplate output voltage of less than 6 volts and a nameplate output current greater than or equal to 550 milliamperes" Reference "Regulation (EU) 2019/1782 laying down ecodesign requirements for external power supplies pursuant to Directive 2009/125/EC "
    source d’alimentation externe à basse tension | SAE basse tension
    fr
    Definition "source d’alimentation externe dont la tension de sortie figurant sur la plaque signalétique est inférieure à 6 volts et dont le courant figurant sur la plaque signalétique est supérieur ou égal à 550 milliampères" Reference "COM-FR, d'après: - règlement (UE) 2019/1782 établissant des exigences d’écoconception pour les sources d’alimentation externe en vertu de la directive 2009/125/CE- document interne ENER-2025-00261"
  5. ENERGY|electrical and nuclear industries|electrical industry · INDUSTRY|electronics and electrical engineering
    acmhainn feidhmiúcháin le linn ísealvoltais Reference "Faofa ag an gCoiste Téarmaíochta, www.tearma.ie ;Faomhadh an téarma seo mar chuid de Thionscadal Lex"
    ga
    FRT-Fähigkeit | Fähigkeit zum Durchfahren eines Fehlers | „Fault-Ride-Through“-Fähigkeit
    de
    Definition Fähigkeit eines Generators, den synchronen Betrieb aufrechtzuerhalten, wenn eine schwere Störung in der elektrischen Umgebung des Generators auftritt Reference "ABB > Dialogseite: ""Sind Netzstabilität und Grid-Codes ein interessantes Thema?"", 2014, http://www.abb-conversations.com/DACH/2014/09/ist-netzstabilitat-und-sind-grid-codes-fur-euch-ein-thema/ (25.6.2015)"
    fault ride through | fault-ride-through | low voltage ride through | fault ride through capability
    en
    Definition capability of electrical devices, especially wind generators, to be able to operate through periods of lower grid voltage Reference "Wikipedia > Low-voltage ride-through. http://en.wikipedia.org/wiki/Low_voltage_ride_through [16.4.2015]"
    Comment Similar requirements for critical loads such as computer systems and industrial processes are often handled through the use of an uninterruptible power supply (UPS) to supply make-up power during these events.
    Comment "Wikipedia > Low-voltage ride-through. http://en.wikipedia.org/wiki/Low_voltage_ride_through [16.4.2015]"
    tenue aux creux de tension
    fr
  6. ENERGY|electrical and nuclear industries|electrical industry
    voltas cosantach rí-íseal Reference Faomhadh an téarma seo mar chuid de Thionscadal Lex
    ga
    PELV Reference Faomhadh an téarma seo mar chuid de Thionscadal Lex
    ga
    schützende Kleinspannung | Funktionskleinspannung mit sicherer Trennung | PELV
    de
    Definition ein elektrisches System, in dem die Spannung die Grenzwerte für Kleinspannung sowohl unter normalen Bedingungen als auch unter Einzelfehlerbedingungen ausgenommen bei Erdschlüssen in anderen Stromkreisen, nicht überschreitet Reference "HEA-Fachgemeinschaft für effiziente Energieanwendung e.V. > SERVICE > Fachwissen > Elektroinstallation > Schutzmaßnahmen - Grundlagen > 2.1.2 Schutz gegen elektrischen Schlag (Teil 410) http://www.hea.de/service/fachwissen/elektroinstallation/2-1-schutzmassnahmen-grundlagen.php (3.9.2015)"
    protective extra-low voltage | protected extra low voltage | PELV
    en
    Definition "An extra-low voltage system which is not electrically separated from Earth, but which otherwise satisfies all the requirements for SELV [ IATE:780103 ]" Reference "Ware, J., Protection Against Electric Shock, IET publication, http://www.google.be/url?sa=t&rct=j&q=&esrc=s&frm=1&source=web&cd=1&cad=rja&uact=8&ved=0CCIQFjAAahUKEwjMxMTL3LLHAhUDiywKHWduAio&url=http%3A%2F%2Felectrical.theiet.org%2Fwiring-matters%2F26%2Felectric-shock.cfm%3Ftype%3Dpdf&ei=MjHTVczjH4OWsgHn3InQAg&usg=AFQjCNFIuflXH25fqx7IQoabDBybmJig0Q [18.8.2015]"
    Comment """Protection by extra-low voltage provided by SELV or PELV requires all of the following:- Limitation of voltage in the SELV or PELV system to the upper limit of voltage Band I which is 50 V a.c. or120 V d.c. and- Protective separation of the SELV or PELV system from all circuits other than SELV and PELV circuits, and- Basic insulation between the SELV or PELV system and other SELV or PELV systems, and- For SELV systems only, basic insulation between the SELV system and Earth."""