ga crómatagrafaíocht gháis/mais-speictriméadracht TAGAIRT Faomhadh an téarma seo mar chuid de Thionscadal Lex
en GC/MS | gas chromatography/mass spectrometry | gas chromatography-mass spectrometry | GC-MS | gas chromatography/mass spectroscopy
SAINMHÍNIÚ two techniques that are combined to form a single method of analyzing mixtures of chemicals TAGAIRT George Mason University. Gas Chromatography-Mass Spectroscopy. Background http://www.gmu.edu/departments/SRIF/tutorial/gcd/gc-ms2.htm [17.11.2009]
NÓTA Gas chromatography ( IATE:1350135 ) separates the components of a mixture and mass spectroscopy ( IATE:1364881 ) characterizes each of the components individually. By combining the two techniques, an analytical chemist can both qualitatively and quantitatively evaluate a solution containing a number of chemicals.
de Gaschromatographie/Massenspektrometrie | GC-MS | Gaschromatographie in Verbindung mit der Massenspektrometrie | Gaschromatographie-Massenspektrometrie | GC/MS
SAINMHÍNIÚ Die Gaschromatographie eignet sich zur Bestimmung aller gasförmigen o. unzersetzt verdampfbaren Stoffe, also im wesentlichen von organischen Verbindungen. Eine Probe des zu untersuchenden Stoffgemisches wird in einen Trägergasstrom gebracht und durchströmt eine Trennsäule oder -kapillare mit einer speziellen Füllung bzw. Beschichtung. Stoffabhängige Wechselwirkungen in der Säule bewirken, daß die einzelnen Verbindungen unterschiedlich lange zurückgehalten werden und am Ende der Säule zeitlich getrennt austreten. Zur Detektion der austretenden Komponenten stehen verschiedene Techniken zur Verfügung. Mit einem nachgeschalteten Massenspektrometer lassen sich gleichzeitig Aussagen über Art und Menge der jeweiligen Substanz machen (Identifizierung und Quantifizierung). Dazu werden die austretenden Teilchen ionisiert und die gebildeten Molekülionen, die zum Teil zerfallen, entsprechend ihrem Verhältnis Masse/Ladung in einem Magnetfeld aufgetrennt. Das Muster der auftretenden Fragmente kann einem bestimmten Stoff zugeordnet werden. (Quelle s.o.)
NÓTA DIV: hym 13/11/2002
Chemistry
ga crómatagrafaiocht gháis in éineacht le mais-speictriméadracht ardtaifeach TAGAIRT Faomhadh an téarma seo mar chuid de Thionscadal Lex
en gas chromatography high-resolution mass spectrometry
SAINMHÍNIÚ analytical technique coupling gas chromatography<sup>1</sup> to high-resolution mass spectrometry<sup>2</sup><HR><sup>1</sup> gas chromatography [ IATE:1350135 ]<BR><sup>2</sup> high-resolution mass spectrometry [ IATE:3509898 ] TAGAIRT COM-Terminology Coordination, based on:<BR>Ferrer & Thurman (Editors). <i>Advanced Techniques in Gas Chromatography-Mass Spectrometry (GC-MS-MS and GC-TOF-MS) for Environmental Chemistry, 1st Edition</i>, ISBN: 9780444626233 <BR> http://store.elsevier.com/product.jsp?lid=0&iid=73&sid=0&isbn=9780444626240 & http://books.google.fr/books?id=4QZKxfvxg0cC&pg=PA185&lpg=PA185&dq=gc-hrms&source=bl&ots=FfzivaYhkV&sig=9JsR0HM74LNuZQLJKb-EY3Y5Gzs&hl=en&sa=X&ei=0tgWU66oC6SEyAOckoGgDA&ved=0CDwQ6AEwAzgU#v=onepage&q=gc-hrms&f=false [5.3.2014]
fr chromatographie gazeuse couplée à la spectrométrie de masse à haute résolution
SAINMHÍNIÚ technique d'analyse associant la <I>chromatographie gazeuse</I> [IATE:1350135] à la spectrométrie de masse à haute résolution TAGAIRT COM-FR, d'après diverses sources.
mul GC-HRMS
Chemistry
ga CGMSS TAGAIRT Faomhadh an téarma seo mar chuid de Thionscadal Lex
ga crómatagrafaiocht gháis in éineacht le mais-speictriméadracht sraithe TAGAIRT Faomhadh an téarma seo mar chuid de Thionscadal Lex
en gas chromatograph-tandem mass spectrometry | gas chromatography-tandem mass spectrometry | gas chromatograph-tandem mass spectrometer
SAINMHÍNIÚ analytical technique coupling gas chromatography<sup>1</sup> to tandem mass spectrometry<sup>2</sup><HR><sup>1</sup> gas chromatography [ IATE:1350135 ]<BR><sup>2</sup> tandem mass spectrometry [ IATE:157399 ] TAGAIRT COM-Terminology Coordination, based on:<BR>Renata Raina and Patricia Hall. <i>Comparison of Gas Chromatography-Mass Spectrometry and Gas Chromatography-Tandem Mass Spectrometry with Electron Ionization and Negative-Ion Chemical Ionization for Analyses of Pesticides at Trace Levels in Atmospheric Samplesy<i>. Anal Chem Insights 2008; 3: 111-125, http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2701172/ [5.3.2014]
Chemistry
ga crómatagrafaíocht gháis ardtaifigh/mais-speictriméadracht ardtaifigh chaolaithe iseatópaigh TAGAIRT Faomhadh an téarma seo mar chuid de Thionscadal Lex
ga caolú iseatópach HRGC/HRMS TAGAIRT Faomhadh an téarma seo mar chuid de Thionscadal Lex
en isotope dilution high resolution gas chromatography/high resolution mass spectrometry | isotope dilution HRGC/HRMS
NÓTA For the method, see: EPA Method 1613 revision B. Tetra- through Octa-Chlorinated Dioxins and Furans by Isotope Dilution HRGC/HRMS http://www.epa.gov/waterscience/methods/method/dioxins/1613.pdf [4.11.2009]