Gaois

Search direction

Search mode

Filter results

Collections

13 results in 2 documents

  1. #2511069

    PEAD Bulc-choimeádán idirmheánach (BCI): 650 L, 800 L, 1000 L, 1250 L

    HDPE Intermediate bulk container (IBC): 650 L, 800 L, 1000 L, 1250 L

    Commission Implementing Regulation (EU) 2022/1434 of 22 July 2022 granting a Union authorisation for the biocidal product family ‘CMIT-MIT Aqueous 1.5-15’ (Text with EEA relevance)

  2. #2623764

    Foscríbhinn 4 - Tástáil BCI

    Appendix 4 - BCI test

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  3. #2624204

    Cuid 4 : Instealladh srutha toirte (BCI) (ISO 11451-4, tríú heagrán 2013).

    Part 4 : Bulk current injection (BCI) (ISO 11451-4, third edition 2013).

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  4. #2624209

    Cuid 4 : Instealladh srutha toirte (BCI) (ISO 11452-4, ceathrú heagrán 2011);

    Part 4 : Bulk current injection (BCI) (ISO 11452-4, fourth edition 2011);

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  5. #2625122

    Tástáil BCI

    BCI test

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  6. #2623968

    Má dhéantar tástálacha ag baint úsáid as na modhanna ar a dtugtar tuairisc in Iarscríbhinn 9, is é a bheidh sna leibhéil tástála imdhíonachta 60 volta/m meán cuadratach cearnaigh (rms) le haghaidh an mhodh tástála líne stéille 150 mm, 15 volta/m rms le haghaidh an mhodh tástála líne stéille 800 mm, 75 volta/m rms le haghaidh an mhodh tástála ceall de Mhód Trasnach Leictreamaighnéadach (TEM), 60 mA rms le haghaidh an mhodh tástála insteallta srutha toirte (BCI) agus 30 volta/m rms le haghaidh an mhodh tástála saor-réimse i thart ar 90 faoin gcéad den bhanda minicíochta idir 20 agus 2 000 MHz, agus suas le híosmhéid de 50 volta /m rms le haghaidh an mhodh tástála líne stéille 150 mm, 12.5 volta/m rms le haghaidh an mhodh tástála líne stéille 800 mm, 62.5 volta/m rms, le haghaidh an mhodh tástála ceall TEM, 50 mA rms le haghaidh an mhodh tástála insteallta srutha toirte (BCI) agus 25 volta/m rms le haghaidh an mhodh tástála saor-réimse ar fud an bhanda minicíochta idir 20 agus 2 000 MHz ina iomláine.

    If tests are made using the methods described in Annex 9, the immunity test levels shall be 60 volts/m root-mean-square (rms) for the 150 mm stripline testing method, 15 volts/m rms for the 800 mm stripline testing method, 75 volts/m rms for the Transverse Electromagnetic Mode (TEM) cell testing method, 60 mA rms for the bulk current injection (BCI) testing method and 30 volts/m rms for the free field testing method in over 90 per cent of the 20 to 2,000 MHz frequency band, and to a minimum of 50 volts/m rms for the 150 mm stripline testing method, 12.5 volts/m rms for the 800 mm stripline testing method, 62.5 volts/m rms, for the TEM cell testing method, 50 mA rms for the bulk current injection (BCI) testing method and 25 volts/m rms for the free field testing method over the whole 20 to 2,000 MHz frequency band.

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  7. #2624148

    Má dhéantar tástálacha ag baint úsáid as na modhanna ar a dtugtar tuairisc in Iarscríbhinn 9, is é a bheidh sna leibhéil tástála imdhíonachta 60 volta/m rms le haghaidh an mhodh tástála líne stéille 150 mm, 15 volta/m rms le haghaidh an mhodh tástála líne stéille 800 mm, 75 volta/m rms le haghaidh an mhodh tástála ceall de Mhód Trasnach Leictreamaighnéadach (TEM), 60 mA rms le haghaidh an mhodh tástála Insteallta Srutha Toirte (BCI) agus 30 volta/m rms le haghaidh an mhodh tástála saor-réimse i thart ar 90 faoin gcéad den bhanda minicíochta idir 20 agus 2 000 MHz, agus suas le híosmhéid de 50 volta /m rms le haghaidh an mhodh tástála líne stéille 150 mm, 12.5 volta/m rms le haghaidh an mhodh tástála líne stéille 800 mm, 62.5 volta/m rms, le haghaidh an mhodh tástála ceall TEM, 50 mA rms le haghaidh an mhodh tástála insteallta srutha toirte (BCI) agus 25 volta/m rms le haghaidh an mhodh tástála saor-réimse ar fud an bhanda minicíochta idir 20 agus 2 000 MHz ina iomláine.

    If tests are made using the methods described in Annex 9, the immunity test levels shall be 60 volts/m rms for the 150 mm stripline testing method, 15 volts/m rms for the 800 mm stripline testing method, 75 volts/m rms for the Transverse Electromagnetic Mode (TEM) cell testing method, 60 mA rms for the Bulk Current Injection (BCI) testing method and 30 volts/m rms for the free field testing method in over 90 per cent of the 20 to 2,000 MHz frequency band, and to a minimum of 50 volts/m rms for the 150 mm stripline testing method, 12.5 volts/m rms for the 800 mm stripline testing method, 62.5 volts/m rms, for the TEM cell testing method, 50 mA rms for the bulk current injection (BCI) testing method and 25 volts/m rms for the free field testing method over the whole 20 to 2,000 MHz frequency band.

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  8. #2625030

    Modh tástála BCI leis an modh ionadaíochta agus tóireadóir insteallta suite ag fad 150 m ón ESA;

    BCI test method with substitution method and injection probe positioned at 150 mm distance to the ESA;

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  9. #2625031

    Modh tástála BCI leis an modh lúbiata agus tóireadóir insteallta suite ag fad 900 m ón ESA.

    Or BCI test method with closed loop method and injection probe positioned at 900 mm distance to the ESA.

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  10. #2625033

    Modh tástála BCI leis an modh ionadaíochta agus tóireadóir insteallta suite ag fad 150 m ón ESA.

    BCI test method with substitution method and injection probe positioned at 150 mm distance to the ESA.

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  11. #2625039

    Beidh úim sreangaithe ardvoltais/ísealvoltais díreach os cionn a fhad iomláin le haghaidh mhodh tástála BCI ag úsáid an mhodha lúbiata le srian cumhachta.

    The HV/LV wiring harness shall be straight over its entire length for the BCI test method using the closed-loop method with power limitation.

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  12. #2624760

    Má tá feithicil níos faide ná 12 m agus/nó níos leithne ná 2.60 m agus/nó níos airde ná 4.00 m, úsáidfear modh BCI (instealladh srutha toirte) de réir ISO 11451-4 sa raon minicíochta idir 20 agus 2000 MHz le leibhéil arna sainiú i mír 6.8.2.1. den Rialachán seo.

    If a vehicle is longer than 12 m and/or wider than 2.60 m and/or higher than 4.00 m, BCI (bulk current injection) method according to ISO 11451-4 shall be used in the frequency range 20 to 2,000 MHz with levels defined in paragraph 6.8.2.1. of this Regulation.

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]

  13. #2625037

    Beidh úim sreangaithe ardvoltais/ísealvoltais díreach os cionn ag airde 1 400 mm ar a laghad ag tosú ag an ESA le haghaidh gach modh tástála a shainítear i gcuid 4 de ISO 11452 ach amháin modh tástála BCI ag úsáid an mhodha lúbiata le srian cumhachta.

    The HV/LV wiring harness shall be straight over at least 1,400 mm starting at the ESA for all test methods defined in part 4 of ISO 11452 except for the BCI test method using the closed-loop method with power limitation.

    UN Regulation No. 10 – Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility [2022/2263]