This is a static copy of data that is exported from IATE on an occasional basis. It should not be assumed that information provided about an entry here will always correspond to the current version of the entry in IATE. That current version can be checked by clicking on the link on the upper right hand side of each entry. More information »

1 result

  1. SOCIAL QUESTIONS|health|medical science
    gnóthú dealraitheach bithmheasúnachta Reference Faomhadh an téarma seo mar chuid de Thionscadal Lex
    ga
    beobachtete Bioassay-Wiederfindung
    de
    Definition BEQ-Gehalt, berechnet anhand einer TCDD-Kalibrierkurve oder einer PCB-126-Kalibrierkurve nach Korrektur um den Blindwert, geteilt durch den mittels des Bestätigungsverfahrens bestimmten TEQ-Wert. Reference "Verordnung (EU) 2017/644 der Kommission vom 5. April 2017 zur Festlegung der Probenahmeverfahren und Analysemethoden für die Kontrolle der Gehalte an Dioxinen, dioxinähnlichen PCB und nicht dioxinähnlichen PCB in bestimmten Lebensmitteln sowie zur Aufhebung der Verordnung (EU) Nr. 589/2014, CELEX:32017R0644/DE"
    Comment "Siehe auch: - BEQ [ IATE:3539126 ]- TCDD [ IATE:133291 ] - PCB [ IATE:1411349 ]- TEQ [ IATE:1055272 ]"
    bioassay apparent recovery
    en
    Definition "BEQ [ IATE:3539126 ] level calculated from the TCDD [ IATE:133291 ] or PCB 126 calibration curve corrected for the blank and then divided by the TEQ [ IATE:1055272 ] level determined by the confirmatory method" Reference "Regulation (EU) 2017/644 laying down methods of sampling and analysis for the control of levels of dioxins, dioxin-like PCBs and non-dioxin-like PCBs in certain foodstuffs, CELEX:32017R0644/EN"
    Comment "PCB 126 = 3,3',4,4',5-Pentachlorobiphenyl (CAS No. 57465-28-8).It attempts to correct factors like the loss of PCDD/Fs and dioxin-like compounds during the extraction and clean-up steps, co-extracted compounds increasing or decreasing the response (agonistic and antagonistic effects), the quality of the curve fit, or differences between the TEF and the REP values. The bioassay apparent recovery is calculated from suitable reference samples with representative congener patterns around the maximum or action level, CELEX:32017R0644/EN"
    taux de récupération apparent du bioessai
    fr
    Definition "valeur BEQ [ IATE:3539126 ] calculée à partir de la courbe d'étalonnage de la TCDD [ IATE:133291 ] ou du PCB [ IATE:1411349 ] 126 corrigée du blanc, puis divisée par la valeur TEQ [ IATE:1055272 ] déterminée par GC/HRMS [ IATE:3555880 ]" Reference COM-Document interne: SANCO-2013-80586, Règlement de la Commission portant fixation des méthodes de prélèvement et d'analyse d'échantillons à utiliser pour le contrôle des teneurs en dioxines, en PCB de type dioxine et en PCB autres que ceux de type dioxine de certaines denrées alimentaires et abrogeant le règlement (UE) n° 252/2012