Gaois

This is a static copy of data that is exported from IATE on an occasional basis. It should not be assumed that information provided about an entry here will always correspond to the current version of the entry in IATE. That current version can be checked by clicking on the link on the upper right hand side of each entry. More information »

1 result

  1. SCIENCE|natural and applied sciences|physical sciences|chemistry|analytical chemistry
    éadáil neamhspleách ar shonraí Reference Faomhadh an téarma seo mar chuid de Thionscadal Lex
    ga
    Context 'Nuair a dhéantar cinneadh mais-speictriméadrach trí bhloghadh tar éis máthair-ian a roghnú, déantar máthair-ian a roghnú de réir taifeach aonaid maise nó níos fearr. Is éard a bheidh sa mháthair-ian a roghnófar an t-ian móilíneach, aduchtanna saintréitheacha den ian móilíneach, mac-iain shaintréitheacha nó ceann dá n-iain iseatóip. I gcás ina ngabhann ionú maisroghnúcháin níos mó ná aon Dalton amháin le máthair-iain a roghnú (e.g. i gcás Éadáil Neamhspleách ar Shonraí) meastar gur anailís dheimhnitheach lánscanta í an teicníc.' Reference Rialachán Cur Chun Feidhme (AE) 2021/808 maidir le modhanna anailíse a fheidhmiú i leith iarmhair substaintí atá gníomhach ó thaobh na cógaseolaíochta de agus a úsáidtear i mbia-ainmhithe agus maidir torthaí a léirmhíniú agus maidir leis na modhanna atá le húsáid le haghaidh samplála agus lena n-aisghairtear Cinneadh 2002/657/CE agus Cinneadh 98/179/CE, CELEX:32021R0808/GA
    DIA | data-independent acquisition
    en
    Definition method of identification and/or quantification due to the continuous collection of fragment-ion spectra over a preselected precursor m/z range Reference COM-Terminology Coordination, based on: Heaven MR, Funk AJ, Cobbs AL, et al., 'Systematic evaluation of data-independent acquisition for sensitive and reproducible proteomics-a prototype design for a single injection assay' (12.2.2021), Journal of Mass Spectrometry, 2016;51(1):1-11. doi:10.1002/jms.3716
    Comment Multiple variations of the DIA approach have been applied; for a review see Tate et al.[17] For instance, in the MSE method,[12] high and low collision energy is used to fragment all precursors simultaneously from 400–1200 m/z. Whereas, in the sequential windowed acquisition of all theoretical fragment-ions (SWATH)[13] procedure, 26 m/z windows are stepped through every ~3 seconds covering the 400–1200 m/z precursor range in a single analysis. Other methods such as precursor acquisition independent from ion count (PAcIFIC)[14] use isolation windows as small as 2.5 m/z that provide ideal sensitivity and specificity, but require many analyses to assay the 400–1400 precursor m/z range (e.g., in each sample injection a 15 m/z precursor range is analyzed). Although these extreme differences in isolation windows sizes have been applied from 2.5 to 800 m/z in the PAcIFIC and MSE methods, respectively, systematic evaluation of this important parameter in various DIA methods and the precursor m/z ranges analyzed have not been reported.