Gaois

Cóip statach de shonraí a easpórtáiltear ó IATE ó am go chéile atá sa chnuasach seo. Níor cheart glacadh leis gurb ionann i gcónaí an t-eolas a thugtar faoi iontráil anseo agus a bhfuil sa leagan reatha den iontráil ar IATE. Is féidir an leagan reatha sin a cheadú ach cliceáil ar an nasc atá ar thaobh na láimhe deise ag barr gach iontrála. Breis eolais »

1 toradh

  1. SCIENCE|natural and applied sciences|physical sciences|chemistry
    críochphointe Tagairt Faomhadh an téarma seo mar chuid de Thionscadal Lex
    ga
    Endpunkt | Titrationsendpunkt
    de
    Sainmhíniú derjenige Punkt bei einer Titration, bei dem sich eine ausgewählte Eigenschaft der Lösung (z. B. die ihr durch einen Indikator verliehene Farbe ...) deutlich ändert Tagairt "Thieme RÖMPP Online, Eintrag zu ""Endpunkt"", Thieme, 2010, https://roempp.thieme.de/roempp4.0/do/data/RD-05-01085 (20.7.2017)"
    Nóta "Der Endpunkt liegt mehr oder weniger direkt am Äquivalenzpunkt (theoretischer Endpunkt). Bei der graphischen Methode der Bestimmung des Endpunktes wird dieser als Schnittpunkt von zwei Geraden oder Kurven erhalten.Quelle: Thieme RÖMPP Online, Eintrag zu ""Endpunkt"", Thieme, 2010, https://roempp.thieme.de/roempp4.0/do/data/RD-05-01085 (20.7.2017).Siehe auch: - Äquivalenzpunkt [ IATE:1581531 ]- Titration [ IATE:1594555 ]"
    endpoint | end point
    en
    Sainmhíniú the point in the titration once the equivalence point has been reached, indicated by some form of indicator which varies depending on the type of titration being done Tagairt "UC Davis, Titration Fundamentals, http://chemwiki.ucdavis.edu/Analytical_Chemistry/Quantitative_Analysis/Titration/Titration_Fundamentals [20.11.2015]"
    Nóta "If a color indicator is used, the solution will change color when the titration is at its end point.The endpoint of a titration is NOT the same thing as the equivalence point. The equivalence point is a single point defined by the reaction stoichiometry as the point at which the base (or acid) added exactly neutralizes the acid (or base) being titrated. The endpoint is defined by the choice of indicator as the point at which the colour changes. Depending on how quickly the colour changes, the endpoint can occur almost instantaneously or be quite wide. If an appropriate indicator is chosen such that the endpoint of the titration occurs at the equivalence point, then a colour change in the solution being titrated can be used as a signal that the equivalence point has been reached. The volume of titrant needed to reach the equivalence point can then be read, allowing us to calculate concentrations, volumes, Ka's etc.See also:- equivalence point [ IATE:1581531 ]- titration [ IATE:1594555 ]"
    point de virage | point final du titrage | point équivalent | point d'équivalence
    fr